Home » Products » Insulation Sleeve » Silicone Resin Coated Fiberglass Insulation Sleeve

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
sharethis sharing button

Silicone Resin Coated Fiberglass Insulation Sleeve

Silicone resin coated fiberglass insulation sleeving is manufactured from non-alkali fiberglass yarn woven into a tubular braid, then coated with silicone rubber and cured at high temperature. The finished construction places the fiberglass braid on the inside and the silicone resin on the outside, so the sleeve carries the mechanical and thermal strength of glass fiber together with the dielectric and flexibility of silicone.

The sleeving is produced in four dielectric grades — 1,500 V, 2,500 V, 4,000 V and 7,000 V — each built to a different fiberglass-to-silicone ratio of 9:1, 5:2, 10:7 and 5:5 respectively. Wall thickness and breakdown strength therefore scale with the working voltage of the application instead of forcing one heavy wall onto every design, which keeps bundle diameter and cost under control on low-voltage harnesses while still meeting 7,000 V isolation requirements on the same production line.

Continuous service temperature is -40 ℃ to +200 ℃. The sleeve withstands 200 ± 2 ℃ for 72 hours while retaining at least half of its original breakdown voltage, passes a 200 ℃ / 6 h heat aging test without cracking, and shows no cracking after cold bend. Volume resistivity is 1 × 10¹¹ Ω·cm or higher, and the coating does not become sticky, deformed or softened after 24 hours of water immersion.

The material is self-extinguishing in the horizontal flame test, with flame-out within 60 seconds, and is rated VW-1 under UL 1441. Typical use is insulation protection for Class H (180 ℃) and Class N (200 ℃) motor and transformer lead wire, internal wiring of household appliances, electric heating equipment, special lamps and lighting fixtures, and the internal harness of televisions and electronic instruments. Standard color is white; other colors and special specifications are available to order.
Availability:
Quantity:

>> Product Introduction

Silicone glass fiber sleeve is made of non alkali glass fiber yarn woveninto a pipe and coated with silicone resin for high temperature treatment. The silicone glass fiber sleeving produced by our company is made of alkali-free glass fiber yarn woven into a tube, which is then coated with silicone and heat-treated.

The main features aregood dielectric, self extinguishing and flexibility, it is widely usedfor insulation protection ofH & n class motors, household appliances, electric heating equipment, special lamps, TV and electronic instruments.



>> Product Advantage

  • Non-alkali fiberglass braid with silicone resin coating — fiberglass inside, silicone outside, combining mechanical strength with dielectric performance

  • Four dielectric grades from 1,500 V to 7,000 V — average breakdown 1,500 / 2,500 / 4,000 / 7,000 V, individual minimum 1,200 / 2,000 / 2,500 / 5,000 V

  • Continuous service temperature -40 ℃ to +200 ℃ — suits Class H and Class N motor and transformer applications

  • VW-1 flame rating, self-extinguishing within 60 seconds in the horizontal flame test per UL 1441

  • Withstands 200 ± 2 ℃ for 72 hours while retaining ≥ 50 % of original breakdown voltage

  • Heat aging 200 ℃ / 6 h with no cracking, and no cracking after cold bend

  • Volume resistivity ≥ 1 × 10¹¹ Ω·cm for reliable electrical isolation

  • Hydrolytic stability — no stickiness, deformation or softening after 24 h water immersion

  • 30 standard sizes from φ1.0 mm to φ35.0 mm, four wall thickness options per size

  • White as standard, other colors to order; special specifications accepted on bulk orders


>> Technical Parameters

图片1


ltem Speeifications Test methods
Appearance The surface is smooth, the thickness of the silicone resin coating is uniform, and the weaving pattern is clearly visible Visual
Temperature Range -10℃~+200℃ UL standard testing
Temperature Endurance
265±2℃ 168h≥1/2Original value of voltage
UL standard testing
Aging Test 260℃,72h,NO Cracking Test temperature 260℃, 72 hours. Take out and test at room temperature. The average damage is not less than half of the damage voltage value before aging, and there is no crack on the surface.
Cold Bend Test temperature -10℃, no cracks in 1 hour Test temperature -10℃, 1 hour, rewind the test tube around the sleeve of this specification for 6 turns, and there is no crack or peeling on the sleeve surface coating.
Horizontal Flame Test ≤30S Burn with a flame of 1000±50Btu/ft, and place the horizontal casing in contact with the outer flame of the flame for 15 seconds at a time, for 5 consecutive times. The flame shall not spread for more than 30 seconds in any of the five tests and shall be extinguished automatically.
Flammability VW-1 UL1441 Test
Submerge Water Test Non-sticky 、non-deformed 、non-bated After the casing is placed in water for 24 hours, the casing surface does not become sticky, deformed, or softened.
Speeifications Inner diameter Wall thickness Packing
1500V 2500V 4000V 7000V (Meter/Roll)
Φ0.5 0.5+0.3/-0 0.3±0.07 0.33±0.07 0.35±0.07 0.4±0.07 200
Φ0.8 0.8+0.3/-0 0.3±0.07 0.33±0.07 0.35±0.07 0.4±0.07 200
Φ1.0 1.0+0.3/-0 0.3±0.07 0.33±0.07 0.35±0.07 0.4±0.07 200
Φ1.5 1.5+0.3/-0 0.3±0.07 0.33±0.07 0.4±0.07 0.45±0.07 200
Φ2.0 2.0+0.3/-0 0.3±0.07 0.33±0.07 0.45±0.07 0.5±0.07 200
Φ2.5 2.5+0.3/-0 0.3±0.07 0.33±0.07 0.45±0.07 0.5±0.07 200
Φ3.0 3.0+0.3/-0 0.3±0.07 0.35±0.07 0.5±0.07 0.55±0.07 100
Φ3.5 3.5+0.3/-0 0.32±0.07 0.35±0.07 0.5±0.07 0.55±0.07 100
Φ4.0 4.0+0.3/-0 0.32±0.07 0.35±0.07 0.5±0.07 0.55±0.07 100
Φ4.5 4.5+0.3/-0 0.4±0.07 0.45±0.07 0.52±0.07 0.6±0.07 100
Φ5.0 5.0+0.35/-0 0.42±0.07 0.45±0.07 0.52±0.07 0.6±0.07 100
Φ6.0 6.0+0.35/-0 0.45±0.07 0.5±0.07 0.6±0.07 0.65±0.07 100
Φ7.0 7.0+0.5/-0 0.45±0.07 0.5±0.07 0.6±0.07 0.7±0.07 100
Φ8.0 8.0+0.5/-0 0.45±0.07 0.5±0.07 0.6±0.07 0.7±0.07 100
Φ9.0 9.0+0.5/-0 0.5±0.07 0.55±0.07 0.7±0.07 0.75±0.07 50
Φ10 10+0.6/-0 0.5±0.07 0.55±0.07 0.7±0.07 0.8±0.07 50
Φ12 12+0.6/-0 0.5±0.07 0.55±0.07 0.7±0.07 0.8±0.07 50
Φ14 14+0.7/-0 0.5±0.07 0.55±0.07 0.7±0.07 0.8±0.07 50
Φ15 15+0.9/-0 0.5±0.07 0.55±0.07 0.7±0.07 0.8±0.07 50
Φ16 16+0.9/-0 0.5±0.07 0.55±0.07 0.7±0.07 0.8±0.07 50
Φ18 18+0.9/-0 0.6±0.07 0.62±0.07 0.75±0.07 0.83±0.07 50
Φ20 20+1.0/-0.5 0.6±0.07 0.62±0.07 0.75±0.07 0.83±0.07 50
Φ22 20+1.1/-0.5 0.75±0.1 0.8±0.1 0.95±0.1 0.98±0.1 50
Φ25 25+1.5/-1.0 0.75±0.1 0.8±0.1 0.95±0.1 0.98±0.1 25
Φ30 30+1.5/-1.0 1.0±0.15 1.05±0.15 1.1±0.15 1.1±0.15 25


>> Applications


  • Motors & Transformers — Lead wire and internal wiring insulation for Class H (180 ℃) and Class N (200 ℃) motors and transformers. The 4,000 V and 7,000 V grades are specified where winding-to-ground clearances are tight and the sleeve must hold isolation through thermal cycling.

  • Household Appliances — Internal wiring protection in ovens, space heaters, rice cookers, kettles and other heat-generating appliances, where PVC and ordinary heat shrink tubing would soften or fail. The 1,500 V and 2,500 V grades cover most 230 V appliance harnesses.

  • Electric Heating Equipment — Insulation for heating element leads, cartridge heater wiring and thermocouple harnesses. The silicone coating resists the embrittlement that glass braid alone suffers after repeated thermal cycling, and the water immersion test result supports use in humid process environments.

  • Lighting Fixtures — High-temperature insulation for halogen, metal halide, LED driver and fluorescent fixture wiring, including the lamp holder leads where temperatures exceed the limit of standard sleeving.

  • Electronic Instruments — Internal harness bundling and insulation in televisions, audio equipment and precision instruments, where a thin wall, tight bend radius and clean braided appearance are required.

>> Selection Guide


  • Step 1 — Measure the conductor. Measure the outer diameter of the wire, cable or lead bundle you need to insulate, including any existing insulation. Select the sleeve whose nominal inner diameter is equal to or slightly larger than that measurement.

  • Step 2 — Confirm the temperature. Determine the maximum continuous temperature at the point of installation, not the ambient temperature of the enclosure. The sleeve is rated -40 ℃ to +200 ℃ continuous. If the location exceeds 200 ℃, a different product is required.

  • Step 3 — Choose the voltage grade. Match the grade to the highest voltage the insulation will see, then apply your own safety margin: 1,500 V grade (individual minimum 1,200 V) for low-voltage appliance and instrument harnesses; 2,500 V grade (individual minimum 2,000 V) for general appliance and control panel wiring; 4,000 V grade (individual minimum 2,500 V) for motor lead wire and transformer internal wiring; 7,000 V grade (individual minimum 5,000 V) for compact windings and high-reliability applications. Use the individual minimum value, not the average, when calculating margin — the average describes production typical, the individual value defines the guaranteed floor.

  • Step 4 — Check the wall against the space. Four wall thicknesses are available for each size, from 0.31 mm to 1.15 mm depending on grade. On tight bundles, dropping one voltage grade usually recovers 0.1–0.2 mm of wall without compromising the actual working voltage.

  • Step 5 — Specify cut length and color. Standard color is white; other colors are available to order. Sleeving is supplied in 25, 50, 100 or 200 m rolls depending on size, and cut-to-length pieces can be quoted on request.

  • Installation notes

  • Cut with sharp shears or a hot knife. A blunt blade frays the braid and exposes loose glass filaments.

  • Deburr the wire end before insertion; a sharp edge will score the silicone coating from the inside.

  • No heat shrinking is required or possible — this is a slip-on sleeve, not heat shrink tubing. Push the sleeve over the conductor and secure the ends with a tie or by the connector housing.

  • Keep a minimum bend radius of at least 3× the sleeve outer diameter to avoid stressing the coating at the bend.

  • Do not stretch the sleeve beyond its nominal length during installation; glass braid does not recover and the wall thins permanently at the stretched section.



>> FAQ

Q: What is silicone resin coated fiberglass sleeving made of? A: Non-alkali fiberglass yarn is woven into a tubular braid, then coated with silicone rubber and cured at high temperature. The finished sleeve has fiberglass on the inside and silicone resin on the outside. The two raw materials are fiberglass yarn (CAS 65997-17-3, SiO₂ + Al₂O₃ + CaO) and silicone rubber oil (CAS 67763-03-5, [(CH₃)₂SiO]n).

Q: What is the continuous operating temperature range? A: -40 ℃ to +200 ℃ continuous. The sleeve withstands 200 ± 2 ℃ for 72 hours while retaining at least half of its original breakdown voltage, and passes a 200 ℃ / 6-hour heat aging test with no cracking.

Q: What do the 1,500 V, 2,500 V, 4,000 V and 7,000 V grades actually mean? A: They are dielectric grades tested to UL 1441. The 1,500 V grade averages 1,500 V breakdown with an individual minimum of 1,200 V; 2,500 V averages 2,500 V with a 2,000 V minimum; 4,000 V averages 4,000 V with a 2,500 V minimum; 7,000 V averages 7,000 V with a 5,000 V minimum. The average is the production typical, the individual value is the guaranteed floor.

Q: Why does wall thickness change with the voltage grade? A: Because each grade uses a different fiberglass-to-silicone ratio — 9:1 for 1.5 kV, 5:2 for 2.5 kV, 10:7 for 4 kV and 5:5 for 7 kV. The higher the grade, the more silicone solids in the coating and the thicker the wall. This lets a low-voltage harness use a thin, flexible wall instead of the heaviest option.

Q: How do I choose the right inner diameter? A: Measure the outer diameter of the wire or bundle you need to insulate, including existing insulation, then select the nominal inner diameter that is equal to or slightly larger. Standard sizes run from φ1.0 mm to φ35.0 mm in 30 steps. The sleeve is slip-on, not heat shrink, so it will not contract onto the conductor.

Q: Is the sleeve flame retardant and what rating does it carry? A: It is self-extinguishing in the horizontal flame test, with flame-out within 60 seconds, tested to UL 1441, and rated VW-1.

Q: Does the coating survive water or humidity? A: Yes. After 24 hours of immersion the sleeve surface shows no stickiness, no deformation and no softening. Volume resistivity is 1 × 10¹¹ Ω·cm or higher.

Q: What color and packaging are standard? A: White is the standard color; other colors are available to order. φ1.0–φ2.5 mm are supplied at 200 m per roll, φ3.0–φ8.0 mm at 100 m, φ9.0–φ25.0 mm at 50 m and φ30.0–φ35.0 mm at 25 m. Cut-to-length pieces can be quoted.

Q: Can the sleeve be used on Class H and Class N motors? A: Yes. It is intended for insulation protection of internal wiring in Class H (180 ℃) and Class N (200 ℃) motors, and is also used in household appliances, electric heating equipment, lighting fixtures and electronic instruments.

Q: Can you supply test reports, samples and custom specifications? A: Yes. The product specification sheet covering performance parameters, 30 standard sizes and wall thickness per voltage grade can be issued on request, and samples are available for evaluation. Special specifications and custom colors are accepted for bulk orders — contact our sales team with your size, voltage grade, color and quantity.


Product Category